| 30 April |
Today I’ll explain how to move an IBM System i partition between phisical blades; this can be done if you are using an external storage (SAN) and not internal disks..
This is the configuration:
BLADE 6
partition 1 ->Vios
partition 2 ->Galileo (production System i)
partition 3 -> ArchimedeBK (backup partition)
BLADE 7
partition 1 ->Vios
partition 2 -> Archimede (production System i partition)
partition 3 -> GalileoBK (backup partition)
The goal is to move Archimede production partition from BLADE 7 host to ArchimedeBK partition in BLADE6.
First of all power down the partition, then from the BLADE 7 Vios web interface, check what are disks attached to this partition:
then login to the Vios console with padmin user and check the hdisk devices assignment (in my configuration HDISK>1 because hdisk1 is the internal SAS disk)
$ lsmap all
SVSA Physloc Client Partition ID
vhost0 U7778.23X.067976AV1C11 0×00000000
VTD vtopt0
Status Available
LUN 0×8400000000000000
Backing device
Physloc
VTD vtscsi0
Status Available
LUN 0×8100000000000000
Backing device hdisk2
Physloc U78A5.001.WIH68A0P1C11L1T2W200500A0B8500BB8L1000000000000
VTD vtscsi1
Status Available
LUN 0×8200000000000000
Backing device hdisk3
Physloc U78A5.001.WIH68A0P1C11L1T2W200500A0B8500BB8L2000000000000
VTD vtscsi2
Status Available
LUN 0×8300000000000000
Backing device hdisk4
Physloc U78A5.001.WIH68A0P1C11L1T2W200500A0B8500BB8L3000000000000
SVSA Physloc Client Partition ID
vhost1 U7778.23X.067976AV1C12 0×00000000
VTD vttape0
Status Available
LUN 0×8100000000000000
Backing device rmt0
Physloc U78A5.001.WIH68A0P1T5LC000L0
SVSA Physloc Client Partition ID
vhost2 U7778.23X.067976AV1C14 0×00000000
VTD vtopt1
Status Available
LUN 0×8400000000000000
Backing device /var/vio/VMLibrary/AbetSystemi1
Physloc
VTD vtscsi3
Status Available
LUN 0×8100000000000000
Backing device hdisk6
Physloc U78A5.001.WIH68A0P1C11L1T2W200500A0B8500BB8LA000000000000
VTD vtscsi4
Status Available
LUN 0×8200000000000000
Backing device hdisk7
Physloc U78A5.001.WIH68A0P1C11L1T2W200500A0B8500BB8LB000000000000
VTD vtscsi5
Status Available
LUN 0×8300000000000000
Backing device hdisk8
Physloc U78A5.001.WIH68A0P1C11L1T2W200500A0B8500BB8LC000000000000
Now you can remove vtscsiX devices relative to hdisksX
$ rmdev dev vtscsiX Then remove the hdiskX devices
$ rmdev dev hdiskX
Now open the DS storage manager (I have an IBM DS4700 SAN)
Select the Phisical blade containing the partition you want move, on the right, select (once at time) the logical drives and select change mapping and assign to the BLADE 6.
Be carefully to maintain the current LUN ID….
Now login into the Vios console of the second blade (padmin user) and list current devices:
$ lsdev |grep hdisk
hdisk0 Available SAS Disk Drive
hdisk1 Available MPIO Other DS4K Array Disk
we have no disks (or you can see other System i partition’s disks); so scan for new disks:
$ cfgdev
and relist devices
$ lsdev |grep hdisk
hdisk0 Available SAS Disk Drive
hdisk1 Available MPIO Other DS4K Array Disk
hdisk2 Available MPIO Other DS4K Array Disk
hdisk3 Available MPIO Other DS4K Array Disk
hdisk4 Available MPIO Other DS4K Array Disk
On the new blade vios’s web interface we can assign the “new” disks to the preconfigured backup partition by going to the Storage tab, and flagging the relative hdisks
You can now power on the partition on the second blade..
N.B.
this how to require you know what are you doing.
I'm not responsible if you destroy your production machine following my instruction.








2 comments to 'Migrate IBM System i partition..Vmotion like, not “live”)'